Factors affecting the intelligibility of the sound system

The main factors affecting professional audio engineering:

1. Transmission frequency characteristics of the sound reinforcement system (system bandwidth)

2. Volume, reminder and site area of ​​the room

3. Loudness and signal to noise ratio of the audience to the district

Four. Reverberation time of the room

5. The distance from the audience to the speaker

6. The ratio of direct sound to reverberation sound

7. The pointing characteristics of the speaker

Eight. Using the number and layout of speakers

IX. The speed of speech of the speaker

X. Audience's ability to distinguish

Secondary factors affecting professional audio engineering

1. The gender of the speaker

Second, system distortion

System balance state

4. Sound field balance

5. Sound focus and room resonance

6. The direction of the voice reaching the audience

7. Interfering with the direction of the sound source

Eight. Speaker's microphone use technology

IX. The relationship between the speaker's information and the following.

Introduction of Inverter Filter

Rated currents: 6 to 2000A

Stud or terminal block optional (above 250A it is copper bar)

FT330/FT330T series are general purpose filters, suitable for most inverter brands

Could be customized according to the real interference of customer`s working field

Features of Inverter Output Filter

FT330 series is designed according to the frequency characteristics of interference generated by inverter when it works towards power grid or other digital equipment.

Three-stage filtering design, high impedance at broad frequency range due to special magnetic materials adopted.

Assure the smooth operation of other electronic devices in the vicinity, solve the interference problems of inverter;

FT330T series is specially designed according to the frequency characteristics of interference generated by inverter output when it works towards load;

Effectively solve abnormal conditions such as load heating and howling that are easy to occur during long-distance transmission of frequency inverters, and better effect can be achieved with reactors;

Effectively control the common mode interference along the cable to protect load and increase its service life;

Touch-safe terminal block versions are available to meet the high safety requirement of certain special applications;

Copper bar terminals applied for versions above 250A to keep pace with international standard, easy and safe connection;

Optional 520VAC/690VAC (and above) high voltage versions.

Inverter Filter

Inverter Filter

Inverter Filter,Inverter Output Filter,Inverter RFI Filter,Power Inverter Noise Filter

Jinan Filtemc Electronic Equipment Co., Ltd. , https://www.chinaemifilter.com